sevensandeights
ArboristSite Operative
2008 Dolmar 5100s. Great saw, owned since new, well cared for and has been used to cut about 60 cords (full, not face) of firewood. Starting to notice loss of power in the cut and erratic idle but saw does start and run. Stock saw that runs a Dolmar 18" bar and 3/8ths chain (64DL). Carb was "upgraded" to different model Zama that was recommended to me by the guys at Cutting Edge a several years ago that helped my symptoms initially but they are much worse now. Intake boot has the metal insert ring that was added by the factory.
I initially posted about this problem back in 2020 and everyone said to pressure/vacuum test. I didn't have the proper tools at the time so I "solved" problem by getting a new saw! However, I miss running the 5100s so I started tinkering with it again and would like to try and fix it. I do now have pressure tester and have used it on one other saw in the past.
I put a piece of rubber between the intake boot and carb and and muffler and cylinder. I also made custom block off plates to make it easier to see things without the carb/muffler in the way. Mityvac pump connected to impulse nipple. I can't get the saw to hold any pressure at all with either the muffler/carb or block off plates. Checked the Mityvac and it creates pressure when I occlude the nipple.
What I missing? If I'm not doing anything wrong and the saw has this big of a leak, what is the likely culprit? The most saw work I have done has been to change a P&C on a Dolmar 6400 to make it a 7900. Not sure how to get access to the various seals that could be leaking.


I initially posted about this problem back in 2020 and everyone said to pressure/vacuum test. I didn't have the proper tools at the time so I "solved" problem by getting a new saw! However, I miss running the 5100s so I started tinkering with it again and would like to try and fix it. I do now have pressure tester and have used it on one other saw in the past.
I put a piece of rubber between the intake boot and carb and and muffler and cylinder. I also made custom block off plates to make it easier to see things without the carb/muffler in the way. Mityvac pump connected to impulse nipple. I can't get the saw to hold any pressure at all with either the muffler/carb or block off plates. Checked the Mityvac and it creates pressure when I occlude the nipple.
What I missing? If I'm not doing anything wrong and the saw has this big of a leak, what is the likely culprit? The most saw work I have done has been to change a P&C on a Dolmar 6400 to make it a 7900. Not sure how to get access to the various seals that could be leaking.